Callout |
Component Name |
---|---|
Preliminary Procedure
Properly raise and support the vehicle. Refer to Lifting and Jacking the Vehicle. |
|
1 |
Intake Manifold Runner Control Valve Actuator Solenoid Valve Fastener (Qty: 3) Caution: Refer to Fastener Caution.
6 Y (53 lb in) |
2 |
Intake Manifold Runner Control Valve Actuator Solenoid Linkage |
3 |
Intake Manifold Runner Control Valve Actuator Solenoid Procedure
Disconnect the wiring harness electrical connector from the intake manifold runner control valve actuator solenoid. |
Interior Glass
To clean, use a terry cloth fabric dampened with water. Wipe droplets left behind
with a clean dry cloth. Commercial glass cleaners may be used, if necessary, after
cleaning the interior glass with plain water.
Caution
To prevent scratching, never use abrasive cleaners on automotive glass. Abr ...
Camshaft Position Actuator Solenoid Valve Installation
Caution: The camshaft position actuator solenoid valves must be
kept parallel to the engine front cover during removal and installation.
The camshaft position actuator solenoid valves can be damaged if they become
wedged or stuck during this process.
Install the 2̴ ...
Air Cleaner Element Replacement
Removal Procedure
Disconnect mass air flow sensor wiring harness plug (2) from mass air
flow sensor (3).
Unclip mass air flow sensor wiring harness retainer clip from air cleaner
housing (1).
Remove the air cleaner outlet duct clamp̴ ...