Callout |
Component Name |
---|---|
1 |
Secondary Air Injection Pump Inlet Pipe Note: Squeeze the retainer on opposite sides to release. |
2 |
Secondary Air Injection Pump Outlet Pipe Note: Squeeze the retainer on opposite sides to release. |
3 |
Secondary Air Injection Pump Electrical Connector |
4 |
Secondary Air Injection Pump Bolt Caution: Refer to Fastener Caution.
22 Y (16 lb ft) |
5 |
Secondary Air Injection Pump Nut Tighten
22 Y (16 lb ft) |
6 |
Secondary Air Injection Pump |
Dome Lamp Bezel Replacement
Dome Lamp Bezel Replacement
Callout
Component Name
1
Dome Lamp Bezel Cover
Procedures
Grasp the bezel cover and pull downward to remove from the lamp
assembly.
Disconnect the electrical connections, as ne ...
Air Conditioning Compressor and Condenser Hose Replacement (LUW)
Removal Procedure
Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
Disconnect the A/C refrigerant pressure sensor electrical connector.
Remove air conditioning compressor and condenser hose nut (1).
Remove air conditioning compressor ...
Engine Oil Cooler Housing Replacement
Removal Procedure
Drain the engine coolant. Refer to Cooling System Draining and Filling.
Drain the engine oil. Refer to Engine Oil and Oil Filter Replacement.
Remove the exhaust manifold. Refer to Exhaust Manifold with Catalytic
Converter Replacement.
...