Caution:
Use a tire changing machine in order to dismount tires. Do not use hand tools or tire irons alone in order to remove the tire from the wheel. Damage to the tire beads or the wheel rim could result.
Caution:
Do not scratch or damage the clear coating on aluminum wheels with the tire changing equipment. Scratching the clear coating could cause the aluminum wheel to corrode and the clear coating to peel from the wheel.
Caution:
Damage to either the tire bead or the wheel mounting holes can result from the use of improper wheel attachment or tire mounting procedures. It takes up to 70 seconds for all of the air to completely exhaust from a large tire. Failure to follow the proper procedures could cause the tire changer to put enough force on the tire to bend the wheel at the mounting surface. Such damage may result in vibration and/or shimmy, and under severe usage lead to wheel cracking.
Note:
Rim-clamp, sometimes called-European-type tire changers are recommended.
Caution:
When mounting the tires, use an approved tire mounting lubricant. DO NOT use silicon or corrosive base compounds to lubricate the tire bead and the wheel rim. A silicon base compound can cause the tire to slip on the rim. A corrosive type compound can cause tire or rim deterioration.
Warning:
To avoid serious personal injury, do not stand over tire when inflating. The bead may break when the bead snaps over the safety hump. Do not exceed 275 kPa (40 psi) pressure when inflating any tire if beads are not seated. If 275 kPa (40 psi) pressure will not seat the beads, deflate, relubricate the beads and reinflate. Overinflation may cause the bead to break and cause serious personal injury.
Instrument Cluster Upper Bezel Replacement
Instrument Cluster Upper Bezel Replacement
Callout
Component Name
1
Instrument Panel Cluster Upper Bezel
Procedures
Use a flat bladed plastic trim tool in order to disengage the retainers
securing the instrume ...
Tire and Wheel Balancing (Collet Cone Selection)
Important: Never use the hub cap bore to center the wheel onto
the balancer. The pilot bore (on the hub side of the wheel) is machined
to be concentric to very tight non - standard tolerances. The bottom cap
bore is not machined to this same degree of precision.
Accurate mac ...
Case Porosity Repair
Some external leaks are caused by case porosity in non-pressurized areas.
Thoroughly clean the area to be repaired with a cleaning
solvent. Air dry the area.
Warning: Epoxy adhesive may cause skin irritations and eye damage.
Read and follow all information on the container label a ...